Posted By
Christopher Olsen
04-24-2026 03:05 PM
Found In
Egroup:
All Member Open Forum
\
view thread
In my experience, the limiting factor is cycle time of the motors. It is tricky to capture stable vibration data for an FFT on something running for less than a minute. With infrared, short cycles do not usually allow heat to build. You might have success tracking the overalls for vibration and ultrasonics, ...
|